<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>LTECatM1 Αρχεία - Infinite Informatics</title>
	<atom:link href="https://www.infinite.com.gr/case-study-category/ltecatm1/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.infinite.com.gr/case-study-category/ltecatm1/</link>
	<description>IoT Solutions, Cloud Software &#38; Autonomous RTUs</description>
	<lastBuildDate>Wed, 02 Dec 2020 23:20:39 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.infinite.com.gr/wp-content/uploads/2020/11/infinite_SL_0.png</url>
	<title>LTECatM1 Αρχεία - Infinite Informatics</title>
	<link>https://www.infinite.com.gr/case-study-category/ltecatm1/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Earth Fault Monitoring for Power Grids</title>
		<link>https://www.infinite.com.gr/case_study/earth-fault-monitoring-for-power-grids/</link>
		
		<dc:creator><![CDATA[pratos@indinf.gr]]></dc:creator>
		<pubDate>Wed, 02 Dec 2020 23:15:14 +0000</pubDate>
				<guid isPermaLink="false">https://www.infinite.com.gr/?post_type=case_study&#038;p=7435</guid>

					<description><![CDATA[<p>Το άρθρο <a href="https://www.infinite.com.gr/case_study/earth-fault-monitoring-for-power-grids/">Earth Fault Monitoring for Power Grids</a> εμφανίστηκε πρώτα στο <a href="https://www.infinite.com.gr">Infinite Informatics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div id="tm-row-69c4781be38ba" data-vc-full-width="true" data-vc-full-width-init="false" class="vc_row vc_row-outer vc_row-fluid"><div id="tm-column-69c4781be4eb6" class="wpb_column vc_column_container vc_col-sm-1"><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div><div id="tm-column-69c4781be4f97" class="wpb_column vc_column_container vc_col-sm-10"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="tabs" style="text-align: left;">
<p><span style="color: #222222; font-size: 22px; font-weight: bold;"><span style="color: #222222; font-size: 22px; font-weight: bold;">Introduction</span></span></p>
<p>This presentation is dedicated for Earth Fault Monitoring for Power Grids .</p>
<p>Autonomous RTUs: BSC-50D, BSC-50E, ADS-260 SIGFOX, ADS-410.</p>
</div>

		</div>
	</div>
<div class="tm-spacer" id="tm-spacer-69c4781be63a2"></div>
<div id="tm-row-inner-69c4781be73a9" class="vc_row vc_inner vc_row-fluid"><div id="tm-column-inner-69c4781be85dd" class="wpb_column vc_column_container vc_col-sm-1"><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div><div id="tm-column-inner-69c4781be86be" class="wpb_column vc_column_container vc_col-sm-10"><div class="vc_column-inner "><div class="wpb_wrapper"><div class="tm-image  tm-animation move-up" id="tm-image-69c4781be9158">
			<div class="image"><img decoding="async" src="https://www.infinite.com.gr/wp-content/uploads/2020/12/EFD-presentation-624x346.jpg" alt="" /></div>	</div>
</div></div></div><div id="tm-column-inner-69c4781be9df2" class="wpb_column vc_column_container vc_col-sm-1"><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div></div><div class="tm-spacer" id="tm-spacer-69c4781be9e6e"></div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="tabs" style="text-align: left;">
<p>Read the complete application presentation at,</p>
</div>
<div class="region region-content">
<div id="block-system-main" class="block block-system">
<div class="content">
<div id="node-205" class="node node-case-study node-full clearfix">
<div class="content clearfix">
<div class="field field-name-field-doc-case field-type-file field-label-hidden">
<div class="field-items">
<div class="field-item even"><a href="/docs/Presentations/Earth Fault Monitoring EFD v5.pdf" target="_blank" rel="noopener noreferrer"><span class="file"><img decoding="async" class="file-icon" title="application/pdf" src="https://www.infinite.com.gr/modules/file/icons/application-pdf.png" alt="" />Earth Fault Monitoring EFD v5.pdf</span></a></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>

		</div>
	</div>
</div></div></div><div id="tm-column-69c4781be9f4b" class="wpb_column vc_column_container vc_col-sm-1"><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div></div><div class="vc_row-full-width vc_clearfix"></div>
</div><p>Το άρθρο <a href="https://www.infinite.com.gr/case_study/earth-fault-monitoring-for-power-grids/">Earth Fault Monitoring for Power Grids</a> εμφανίστηκε πρώτα στο <a href="https://www.infinite.com.gr">Infinite Informatics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>In situ measurement of soil moisture with SDI-12 sensors</title>
		<link>https://www.infinite.com.gr/case_study/in-situ-measurement-of-soil-moisture-with-sdi-12-sensors/</link>
		
		<dc:creator><![CDATA[it@mms-adv.gr]]></dc:creator>
		<pubDate>Thu, 05 Nov 2020 07:00:20 +0000</pubDate>
				<guid isPermaLink="false">https://www.infinite.com.gr/?post_type=case_study&#038;p=5077</guid>

					<description><![CDATA[<p>Το άρθρο <a href="https://www.infinite.com.gr/case_study/in-situ-measurement-of-soil-moisture-with-sdi-12-sensors/">In situ measurement of soil moisture with SDI-12 sensors</a> εμφανίστηκε πρώτα στο <a href="https://www.infinite.com.gr">Infinite Informatics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div id="tm-row-69c4781beaa34" data-vc-full-width="true" data-vc-full-width-init="false" class="vc_row vc_row-outer vc_row-fluid"><div id="tm-column-69c4781beabb3" class="wpb_column vc_column_container vc_col-sm-1"><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div><div id="tm-column-69c4781beac7b" class="wpb_column vc_column_container vc_col-sm-10"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="tabs"><span style="color: #222222; font-size: 22px; font-weight: bold;">Introduction</span></div>
<div class="region region-content">
<div id="block-system-main" class="block block-system">
<div class="content">
<div id="node-205" class="node node-case-study node-full clearfix">
<div class="content clearfix">
<div class="field field-name-body field-type-text-with-summary field-label-hidden">
<div class="field-items">
<div class="field-item even">
<p>Soil moisture measurements are important for a number of applications and for a number of different reasons. Applications include land slide studies, erosion, water shed studies, climate studies, predicting weather, flood warning, crop quality and yield optimization, irrigation, and soil remediation to name a few.<br />
Measuring soil moisture is important in agriculture to help farmers manage their irrigation systems more efficiently. Not only are farmers able to generally use less water to grow a crop, they are able to increase yields and the quality of the crop by better management of soil moisture during critical plant growth stages.<br />
In situ soil electrical conductivity monitoring is very important in agriculture because the salinity levels in soil moisture can have dramatic effects on crop health and yields. Agricultural soils over time may become sodic or saline and this may dramatically affect the health and yields of the crops. There are techniques that can remove the sodium to improve soil quality and increase crop production.<br />
Time Domain reflectometry (TDR), Time domain transmissometry (TDT), Coaxial Impedance Dielectric Reflectometry (CIDR) and Frequency Domain Reflectometry (FDR) are the main methods used to measure soil moisture content and electrical conductivity. Most of the soil sensors use the SDI-12 serial protocol, allowing for multiple sensors to be connected to a data logger via a single cable.</p>
<h2>ADU-500 Application</h2>
<p>ADU-500, a D-size battery powered RTU/Data Logger, can address several SDI-12 soil sensors for a total of 48 measurement parameters (channels). Powered only by the internal 3.6V Lithium Thionyl battery, it can provide 12V excitation for all connected soil sensors. The restriction for the total current draw of the SDI-12 bus is:</p>
<p>(n-1)*I<sub>IDLE</sub>+I<sub>ACT</sub> &lt; 250mA (at 12V)<br />
where,<br />
n: Nr. of sensors<br />
I<sub>IDLE</sub>: Sensor idle current (quiescent current)<br />
I<sub>ACT</sub>: Sensor active current (during measurement)</p>
</div>
</div>
</div>
<div class="field field-name-field-img-case field-type-image field-label-hidden">
<div class="field-items">
<div class="field-item even"><img decoding="async" src="https://www.infinite.com.gr/wp-content/uploads/2020/10/soil_m_0.jpg" /></div>
</div>
</div>
<div class="field field-name-field-moretext field-type-text-with-summary field-label-hidden">
<div class="field-items">
<div class="field-item even">
<h2>Case study</h2>
<p>In the following example, ADU-500 is used to measure and log air temperature, humidity, precipitation and soil moisture. The ultra low power HT200 sensor is used to measure air temperature and humidity. A tipping bucket rain gauge, connected to the unit digital counter, is used to for the precipitation measurement. SDI-12 soil sensors (6 pieces) are connected to the SDI-12 port, measuring soil moisture, temperature and conductivity at various soil depths. ADU-500 performs data collection according to the selected sampling rate (e.g. every 15 minutes). The sampled data is logged and sent to an internet server via FTP, according to the selected sending rate (e.g. every 6 hours). Alert SMS are sent to predefined users.<br />
The Lithium Thionyl battery lifetime is calculated for different sensor types.</p>
<table>
<tbody>
<tr>
<td>Air temperature</td>
<td>[°C], -40-50°C</td>
</tr>
<tr>
<td>Air humidity</td>
<td>[%] RH, 0-100%</td>
</tr>
<tr>
<td>Rainfall</td>
<td>[mm]</td>
</tr>
<tr>
<td>Parameters per SDI-12 sensor</td>
<td>Soil Moisture [wfv], Soil Conductivity [dS/m], Soil Temperature [°C]</td>
</tr>
<tr>
<td>Nr. of recorded channels</td>
<td>21</td>
</tr>
<tr>
<td>Sampling interval</td>
<td>15 minutes</td>
</tr>
<tr>
<td>Logging rate</td>
<td>1 (every sample = 15 minutes)</td>
</tr>
<tr>
<td>Sending rate</td>
<td>24 (every 24 logs = 6 hours)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th>Manufacturer</th>
<th>Stevens</th>
<th>Decagon</th>
<th>Acclima</th>
<th>Campbell Scientific</th>
</tr>
<tr>
<td>Soil sensor</td>
<td>Hydra Probe II</td>
<td>5TE / GS3</td>
<td>SEN-SDI</td>
<td>CS650 / CS655</td>
</tr>
<tr>
<td>Type</td>
<td>CIDR</td>
<td>FDR</td>
<td>TDT</td>
<td>TDR</td>
</tr>
<tr>
<td>Nr. of sensors</td>
<td>6</td>
<td>6</td>
<td>6</td>
<td>6</td>
</tr>
<tr>
<td>I<sub>IDLE</sub> [mA]</td>
<td>1</td>
<td>0.3</td>
<td>0.015</td>
<td>0.135</td>
</tr>
<tr>
<td>I<sub>ACT</sub> [mA]</td>
<td>10</td>
<td>10 / 25</td>
<td>30</td>
<td>45</td>
</tr>
<tr>
<td>Warm up time [sec]</td>
<td>3</td>
<td>3</td>
<td>3</td>
<td>3</td>
</tr>
<tr>
<td>Measurement time [sec]</td>
<td>2</td>
<td>0.15</td>
<td>0.45</td>
<td>0.003</td>
</tr>
<tr>
<td>Battery Lifetime [Years]<sup>1)</sup></td>
<td>1.2</td>
<td>5 / 4</td>
<td>2.5</td>
<td>6.6</td>
</tr>
</tbody>
</table>
<p><sup>1)</sup> Calculations are based on the sensor manufacturer&#8217;s specifications.</p>
<p>Read more at,</p>
<p><img decoding="async" class="file-icon" title="application/pdf" src="https://www.infinite.com.gr/modules/file/icons/application-pdf.png" alt="" /> <a href="/docs/Case_Studies/In situ measurement of soil moisture.pdf" target="_blank" rel="noopener noreferrer" type="application/pdf; length=72034">In situ measurement of soil moisture.pdf</a></p>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>

		</div>
	</div>
</div></div></div><div id="tm-column-69c4781beae71" class="wpb_column vc_column_container vc_col-sm-1"><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div></div><div class="vc_row-full-width vc_clearfix"></div>
</div><p>Το άρθρο <a href="https://www.infinite.com.gr/case_study/in-situ-measurement-of-soil-moisture-with-sdi-12-sensors/">In situ measurement of soil moisture with SDI-12 sensors</a> εμφανίστηκε πρώτα στο <a href="https://www.infinite.com.gr">Infinite Informatics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>