<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>WiFi Αρχεία - Infinite Informatics</title>
	<atom:link href="https://www.infinite.com.gr/case-study-category/wifi/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.infinite.com.gr/case-study-category/wifi/</link>
	<description>IoT Solutions, Cloud Software &#38; Autonomous RTUs</description>
	<lastBuildDate>Thu, 26 Nov 2020 15:18:17 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.infinite.com.gr/wp-content/uploads/2020/11/infinite_SL_0.png</url>
	<title>WiFi Αρχεία - Infinite Informatics</title>
	<link>https://www.infinite.com.gr/case-study-category/wifi/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Freezer data logging &#038; remote monitoring</title>
		<link>https://www.infinite.com.gr/case_study/freezer-data-logging-remote-monitoring/</link>
		
		<dc:creator><![CDATA[it@mms-adv.gr]]></dc:creator>
		<pubDate>Tue, 01 Sep 2020 14:00:50 +0000</pubDate>
				<guid isPermaLink="false">https://www.infinite.com.gr/?post_type=case_study&#038;p=6153</guid>

					<description><![CDATA[<p>Το άρθρο <a href="https://www.infinite.com.gr/case_study/freezer-data-logging-remote-monitoring/">Freezer data logging &#038; remote monitoring</a> εμφανίστηκε πρώτα στο <a href="https://www.infinite.com.gr">Infinite Informatics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div id="tm-row-69c3bafd430bd" class="vc_row vc_row-outer vc_row-fluid"><div id="tm-column-69c3bafd4387c" class="wpb_column vc_column_container vc_col-sm-1"><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div><div id="tm-column-69c3bafd4394a" class="wpb_column vc_column_container vc_col-sm-10"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="tabs">
<div class="field field-name-body field-type-text-with-summary field-label-hidden">
<div class="field-items">
<div class="field-item even">
<div class="tabs">
<div class="tabs">
<div class="tabs"><span style="color: #222222; font-size: 22px; font-weight: bold;">Introduction</span></div>
<div class="region region-content">
<div id="block-system-main" class="block block-system">
<div class="content">
<div id="node-106" class="node node-case-study node-full clearfix">
<div class="content clearfix">
<div class="field field-name-body field-type-text-with-summary field-label-hidden">
<div class="field-items">
<div class="field-item even">
<p>iLOGPlus is a range of data loggers with built in advanced technology features and full Internet connectivity. It is manufactured in 2 versions with built-in Ethernet interface and with a built in GSM modem, that are capable to fit a wide range of applications ranging from simple to the most complex.</p>
<p><img decoding="async" class="size-medium wp-image-6154 aligncenter" src="https://www.infinite.com.gr/wp-content/uploads/2020/10/FDLOG_0-300x146.jpg" alt="" width="300" height="146" srcset="https://www.infinite.com.gr/wp-content/uploads/2020/10/FDLOG_0-300x146.jpg 300w, https://www.infinite.com.gr/wp-content/uploads/2020/10/FDLOG_0.jpg 694w" sizes="(max-width: 300px) 100vw, 300px" /></p>
<h2></h2>
<h2>Requirements</h2>
<p>At an industrial frozen food manufacturer’s site with 2 deep freezers (-25°C) and 1 conservation freezer (0°C) it is desired to:</p>
<ul class="nop">
<li>Measure and log temperature, humidity and receive alerts when limits are exceeded.</li>
<li>Receive alerts whenever there is a power failure.</li>
<li>Receive alerts whenever the freezer doors are left open for a long term.</li>
</ul>
<h2>Proposal</h2>
<p>An iLOGPlus-LAN data logger with</p>
<ul class="nop">
<li>An optional GSM modem to send alarms via SMS,</li>
<li>3 temperature probes (typically AD592 which are current sensors and can be extended up to 100+ meters),</li>
<li>3 humidity probes (typically a 5-95% to 4-20mA),</li>
<li>A power loss detection relay to monitor power failures,</li>
</ul>
<p>is all that is needed to setup a complete monitoring and alerting system.</p>
</div>
</div>
</div>
<div class="field field-name-field-img-case field-type-image field-label-hidden">
<div class="field-items">
<div class="field-item even"></div>
</div>
</div>
<div class="field field-name-field-moretext field-type-text-with-summary field-label-hidden">
<div class="field-items">
<div class="field-item even">
<p>The iLOGPlus data loggers can log all channels and send data automatically to a preconfigured email or local ftp account every x hours. Online monitoring is offered through the internal web server, using any Internet browser.<br />
Whenever there is an alarm e.g. a temperature limit overstepping for more than 30 minutes, an SMS alert to a list of recipients is issued. If the temperature rises above 2°C an SMS alert will be issued to a list of recipients, which can decide and decide on, visiting the installation or issuing remote commands.<br />
Note: A single iLOGPlus data logger, which has by default 4 analogue inputs, 4 digital inputs, and 2 relay digital outputs can manage all the above. Extend the iLOGPlus unit with GE-AI-4 analog input expansion units to add more freezers (up to 16 channels per iLOGPlus device).</p>
<p>Read more at,</p>
</div>
</div>
</div>
<div class="field field-name-field-doc-case field-type-file field-label-hidden">
<div class="field-items">
<div class="field-item even"><span class="file"><img decoding="async" class="file-icon" title="application/pdf" src="https://www.infinite.com.gr/modules/file/icons/application-pdf.png" alt="" /> <a href="/docs/Case_Studies/Freezer datalogging.pdf" target="_blank" rel="noopener noreferrer" type="application/pdf; length=700399">Freezer datalogging.pdf</a></span></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>

		</div>
	</div>
</div></div></div><div id="tm-column-69c3bafd43c30" class="wpb_column vc_column_container vc_col-sm-1"><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div></div>
</div><p>Το άρθρο <a href="https://www.infinite.com.gr/case_study/freezer-data-logging-remote-monitoring/">Freezer data logging &#038; remote monitoring</a> εμφανίστηκε πρώτα στο <a href="https://www.infinite.com.gr">Infinite Informatics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>